Technical Services
Charge Lite Circuit For Alternators
With Integral (Built-In) Regulators
Negative Ground Circuit



12 volts, 1 amp, D. C., Single Pole, normally closed contacts, insulated coil.

Possible Sources:

      Delco No. 115834
      Narton No. 1300-2
      Ford No. D1HS-10A3



RECOMMENDED MIN. WIRE SIZES

SYSTEM
RATING
TOTAL LENGTH OF CHARGING
CIRCUIT
A B
14 V-65 A 12 Feet or less
12 - 20 Feet
#8
#6
#16
#16
14 V-85 A 15 Feet or less
15 Feet - 25 Feet
#6
#4
#16
#16
14 V-105 A 12 Feet or less
12 - 20 Feet
#6
#4
#16
#16
14 V-130 A
14 V-160 A
15 Feet or less
15 25 Feet
#4
#2
#16
#16

©Copyright 1996-2014 Prestolite Electric Inc

Important:

The information supplied could contain technical, typographical or other inaccuracies, and Prestolite assumes no responsibility for errors on this website or on other documents that are referenced by or linked to the publications on this site.

Questions regarding this information should be directed to the customer service division nearest you. Contact information can be found at our website at http://www.prestolite.com/pgs_contact/contact_0.php.