12 volts, 1 amp, D. C., Single Pole, normally closed contacts, insulated coil.
SYSTEM RATING
|
TOTAL LENGTH OF CHARGING CIRCUIT
|
A
|
B
|
|
14 V-65 A
|
12 Feet or less
12 - 20 Feet
|
#8
#6
|
#16
#16
|
|
14 V-85 A
|
15 Feet or less
15 Feet - 25 Feet
|
#6
#4
|
#16
#16
|
|
14 V-105 A
|
12 Feet or less
12 - 20 Feet
|
#6
#4
|
#16
#16
|
14 V-130 A
14 V-160 A
|
15 Feet or less
15 25 Feet
|
#4
#2
|
#16
#16
|